Partition walls with fire protection requirements

Partition walls and facings made up from gypsum blocks are, classified in accordance with DIN 4102-4 and can, without further verification, be allocated to the fire resistance classes in accordance with the table. A test certificate or approval is not required.

The values given are respectively achieved without plaster layers. Electrical installations such as switches or sockets can be installed in the wall without limiting the fire protection; however, they may not be directly opposite to each other on both sides of the wall.

Wall configuration
Thick-
ness
(mm)

Fire
resistance
class
S I N G L E - L E A F   P A R T I T I O N   A N D   S H A F T   W A L L S

60
F 30-A

80
F 120-A

100
F 180-A
D O U B L E - L E A F   P A R T I T I O N   A N D   S H A F T   W A L L S

80 + 60
F 120-A

100 + 60
F 180-A

80 + 80
F 120-A
F A C I N G S

60
F 30-A

80
F 120-A

100
F 180-A